C&K systems ST800L+ Instalační manuál Strana 7

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 16
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 6
6
MOUNTING A REMOTE KEYPAD
1. Choose the keypad location and then mark the holes for mounting.
2. Make sure the cable is run through the backbox.
3. Screw the backbox in the selected position making sure it is not twisted.
WIRING A REMOTE KEYPAD
Use 6 core cable for connection of all remote keypads.
Connect the cable into the terminals shown below in diagram C making
sure each wire goes to a like named terminal in the panel. C goes to C, D to
D, + to + and
- to -. Wire the tamper wires in series with your existing tamper loop.
Individual keypads do not need to be identified to the system. If more than
one remote keypad is used it can be either wired back the control panel or
daisy chained from another keypad. All connections are in parallel with the
exception of the tamper circuit which MUST be wired in series. (see
glossary of terms for series and parallel examples).
DIAGRAM C
POWERING UP
INITIAL POWER UP The lid should remain off the main control panel so
that engineer mode may be used. Alternatively, entering 7890 # can also
be used to enter engineer mode. If the engineers code is entered and the
panel is then left, it will set.
1. Switch the mains supply on, the internal sounder will start. This denotes
a tamper alarm.
2. Enter 1 2 3 4 followed by the # (hash) key - this will silence the
sounder and the TAMPER LED flashes. This has now acknowledged
and cancelled the alarm, however because either the panel or keypad
lid is removed your main tamper loop is open, this is normal.
3. Connect your battery and walk test the control panel. This will make
sure all the zones are clear.
4. Power Down and complete the wiring of the control panel. NEVER wire
the control panel live.
5. Power back up, cancel the alarm and enter engineering mode by
entering 7, 8, 9, 0. The panel is now ready for programming.
6. If no programming is required close any lids that are open and press the
# key. This exits engineering mode. Now refer to the users manual for
customer options.