CK-FG1025Z
The FlexGuard
®
glassbreak detector with
Time-of-Arrival
™
processing.
The FG-1025Z has two microphones which
provide a 160 degree glass zone and 160
degree excluded zone. Only sounds coming
from the glass zone are processed, while all
other sounds are rejected as false alarms
sounds.
Range : 7.6 m
Voltage : 8 ~ 14 Vdc
Current : 25 mA @ 12 Vdc
Operating temperature : 0°C ~ 49ºC
Application : kitchens, restaurants
G
LASS
T
YPE
T
HICKNESS
FG-1008, FG-1015, FG-1025, FG-1025R
AND
FG-1025Z
Minimum size for all glass types is 28 cm x 28 cm square. Glass must
be framed in the wall of the room or mounted in a barrier of 0.9 m
minimum width.
GLASSBREAK ACCESSORIES
CK-FG701 G
LASSBREAK
S
IMULATOR
/T
ESTER
The sound of breaking glass is digitally
simulated by the FG-701 and is compatible
for testing the FG-730 and all FG-1000
series glassbreak detectors. Testing
glassbreak detectors with the FG-701 is
highly recommended upon installation.
Battery type : 9 V Alkaline
Battery life : 2.500 operations
(manual mode)
Output spectral range : 1.5 - 16 kHz
Output level : peak SPL of 102 dB at 1m
Operating temperature : 0°C ~ 50°C
A
CTIVE
I
NFRA
R
ED
B
EAM
D
ETECTORS
TB40 AND TB60 TWIN BEAM PHOTOELECTRIC INTRUSION
DETECTION SYSTEMS
The TB40 and TB60 photoelectric intrusion detection systems are
designed to provide alarm relay activation upon detection of an
intruder moving through a pair of invisible pulsed infrared beams.
Designed for outdoor use, these units feature a sloped cover peak to
avoid frost build-up. The system is stable and reliable in bad weather
conditions such as snow, heavy rain and fog. A built-in
microcomputer works to preserve reliable operation against external
light sources.
CK-TB40
Range indoor : 80 m
Range outdoor : 40 m
Input voltage : 9.8 ~ 28 Vdc
Current draw receiver : 25 mA
Current draw transmitter: 15 mA
Operating temperature : -30°C ~ 60°C
CK-TB60
Range indoor : 120 m
Range outdoor : 60 m
Input voltage : 9.8 ~ 28 Vdc
Current draw receiver : 25 mA
Current draw transmitter: 15 mA
Operating temperature : -30°C ~ 60°C
TB360 AND TB530 DUAL ACTIVE INFRA RED
The TB360 and TB530 are twin (dual) beam active infra-red systems.
Each model is equipped with two transmitters in one housing and two
receivers in another housing. The housings are (normally) mounted in
a vertical position, with one beam above the other. For an alarm
condition to occur, both beams must be broken at the same time - a
requirement that helps prevent false alarms.
CK-TB360
Range indoor : 189 m
Range outdoor : 110 m
Input voltage : 10.5 ~ 28 Vdc
Current draw receiver : 35 mA
Current draw transmitter: 40 mA
Operating temperature : -20°C ~ 60°C
-35°C ~ 60°C;
with optional
heater
7